Showing 126 products.
Range (psi)
15 to 40,000
Reference
G, A
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-65 to +250
Sealing
Hermetic
Output:
Low Level
3 mV/V
Range (psi)
200 to 40,000
Reference
G, A, S
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-65 to +250
Sealing
Hermetic
Output:
Low Level
3 mV/V
Range (psi)
15 to 1,000
Reference
G, A, S
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-65 to +250
Sealing
Hermetic
Output:
Low Level
3 mV/V
Range (psi)
15 to 1,000
Reference
G, A, S
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-65 to +250
Sealing
Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
50 to 40,000
Reference
G, A, S
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-65 to +250
Sealing
Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
50 to 600
Reference
G
Accuracy (%FSO)
±0.25
CTR (°F)
0 to +185
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
15 to 20,000
Reference
G, A
Accuracy (%FSO)
L = ±0.25, H = ±0.25, R = ±0.20
CTR (°F)
-30 to +170
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
200 to 20,000
Reference
G
Accuracy (%FSO)
L = ±0.25, H = ±0.25, R = ±0.20
CTR (°F)
-30 to +170
Output:
Low Level
3 mV/V
Range (psi)
15 to 20,000
Reference
G, A
Accuracy (%FSO)
L = ±0.25, H = ±0.25, R = ±0.20
CTR (°F)
-30 to +170
Output:
Low Level
3 mV/V
Range (lbf)
5,000 to 25,000
Accuracy (%FSO)
0.25
Construction
Tool Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (psi)
200 to 40,000
Reference
G
Accuracy (%FSO)
±0.25
CTR (°F)
-320 to +140
Sealing
Welded
Output:
Analog
4-20 mA (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (psi)
5 to 500
Reference
D
Accuracy (%FSO)
L = ±0.25, H = ±0.25, R = ±0.20
CTR (°F)
-10 to +160
Output:
Low Level
3 mV/V
Range (psi)
50 to 40,000
Reference
D
Accuracy (%FSO)
±0.25
CTR (°F)
+30 to +130
Output:
Low Level
1.5 mV/V
Range (psi)
5 to 500
Reference
D
Accuracy (%FSO)
L = ±0.25, H = ±0.25, R = ±0.20
CTR (°F)
-10 to +160
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
15 to 40,000
Reference
D
Accuracy (%FSO)
±0.25
CTR (°F)
+30 to +130
Output:
Analog
4-20 mA, ±5 Vdc or 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
50 to 5,000
Reference
D (Uni- or Bi-directional)
Accuracy (%FSO)
±0.1 or ±0.2
CTR (°F)
+70 to +170/-30 to +170/-65 to +250
Sealing
IP67/IP68/Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Range (psi)
1 to 500
Reference
D (Uni- or Bi-directional)
Accuracy (%FSO)
±0.15 or ±0.25
CTR (°F)
+70°F to +160°F / -10°F to +160°F
Sealing
IP67/IP68/Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Filters, amplifies, and converts up to 4 channels of mV strain gauge resistor bridge type sensor signals into the selected DC voltage or current output that is linearly related to the input, and field rangeable with a calibration resistor.
Signal conditioner for use with LVDTs requiring AC excitation and synchronous demodulation. Produces outputs of 0-10 Vdc, ±10 Vdc, or 4-20 mA. Incorporates a DC-DC converter to ensure the output of the unit is isolated from the supply.
Single channel amplifier provides variable excitation and signal conditioning mV/V resistor bridge strain gauged sensors. This DIN-rail amplifier provides up to 10V output or 4-20 mA output with transducer signals from 10 mV to 10V.
High reliability DIN-rail signal conditioner for measurement of displacement with an LVDT. It can be used with 4-, 5- and 6-wire LVDTs and provides regulated AC excitation with remote sensing for applications which may require cable lengths greater than 20 feet.
Low cost, general-purpose, field adjustable, single channel conditioner designed for standard DC-excited, mV/V strain gauge transducers. DIN mount construction provides ready access to screw terminal connections for power, analog output, shunt, and sensor signals.
Range (psi)
20 to 50,000
Range (°F)
-320 to 300
Reference
G, A or S
Accuracy (%FSO)
0.25 (Pressure)
Sealing
Welded
Output:
Pressure
mV/V
RTD
1000 Ω
Range (psi)
5 to 20,000
Range (°F)
-320 to 300
Reference
G, A or S
Accuracy (%FSO)
± 0.25 (BFSL)
Temperature Accuracy
±1 (or 1.2 °F)
CTR (°F)
-30 to +170
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
5,000 to 15,000
Range (°F)
32 to 300
Reference
G
Accuracy (%FSO)
±0.20
Temperature Accuracy
±1% (or 1.2 °F)
Construction
Stainless Steel or Inconel
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc, 8-40 Vdc (Non-Isolated)
Digital
CANbus, Modbus, RS-232, RS-485
Range (psi)
2,000 to 10,000
Reference
G
Accuracy (%FSO)
±0.50
CTR (°F)
-65 to +250
Output:
Low Level
3 mV/V
Range (psi)
50 to 10,000
Reference
G
Accuracy (%FSO)
±0.50
CTR (°F)
-30 to +170
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
300 to 10,000
Reference
G, A
Accuracy (%FSO)
±0.10 or ±0.25
CTR (°F)
+70 to +170/-30 to +170/-65 to +250
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Range (psi)
50 to 500
Reference
G, A
Accuracy (%FSO)
±0.10 or ±0.25
CTR (°F)
+70 to +170/-30 to +170/-65 to +250
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Range (psi)
7 to 20,000
Reference
G, A, S
Accuracy (%FSO)
±0.1 or ±0.2
CTR (°F)
+70 to +170/-30 to +170/-65 to +250
Sealing
IP67/IP68/Hermetic
Output:
Low Level
3 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Range (lbf)
100 to 1,000
Accuracy (%FSO)
0.25
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
100 to 1,000
Accuracy (%FSO)
0.25
Construction
Stainless Steel
Tension / Compression
C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
100 to 100,000
Accuracy (%FSO)
0.10 (Linearity)
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Hermetic
Output:
Low Level
3 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (lbf)
100 to 120,000
Accuracy (%FSO)
0.10
Construction
Stainless Steel
Tension / Compression
C
Sealing
Hermetic
Output:
Low Level
3 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (lbf)
5,000 to 120,000
Accuracy (%FSO)
0.20
Construction
Stainless Steel
Tension / Compression
T
Sealing
Hermetic
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (lbf)
2,500 to 50,000
Accuracy (%FSO)
0.25
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Hermetic
Output:
Low Level
1 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (lbf)
10 to 1,000
Accuracy (%FSO)
0.50
Construction
Stainless Steel
Tension / Compression
C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
10 to 1,000
Accuracy (%FSO)
0.50
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
100 to 5,000
Accuracy (%FSO)
0.05
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
3 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (°F)
-320 to 300
Construction
Stainless Steel
Sealing
Welded
Output:
RTD
100 or 1,000 Ω
Range (°F)
-320 to 300
Accuracy (%FSO)
±1 (or 1.2 °F)
Construction
Stainless Steel
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
500 to 20,000
Reference
G, A
Accuracy (%FSO)
±0.10
CTR (°F)
+30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Range (psi)
15 to 40,000
Reference
G, A, D
Accuracy (%FSO)
±0.25
CTR (°F)
+30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Accuracy (%FSO)
Refer to base model series
Construction
Stainless Steel
CTR (°F)
Refer to base model series
Sealing
Welded
Output:
Analog
4-20 mA
Range (lbf)
20,000 to 120,000
Accuracy (%FSO)
0.20
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Hermetic
Output:
Analog
4-20 mA (Integral)
Digital
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral - Non I.S.)
Range (psi)
50 to 50,000
Reference
G, A, S
Accuracy (%FSO)
± 0.10
CTR (°F)
-30 to +170
Sealing
Hermetic
Output:
Low Level
2 mV/V
Range (psi)
50 to 50,000
Reference
G, A, S
Accuracy (%FSO)
±0.10
CTR (°F)
-30 to +170
Sealing
Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
20,000 to 100,000
Reference
G, A
Accuracy (%FSO)
±0.25
CTR (°F)
-30 to +170
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
20,000 to 100,000
Reference
G, A
Accuracy (%FSO)
±0.25
CTR (°F)
-30 to +170
Sealing
Welded
Output:
Low Level
3 mV/V
Range (lbf)
250 to 5,000
Accuracy (%FSO)
0.15
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded (Hermetic Optional)
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
10 to 30,000
Accuracy (%FSO)
0.50
Construction
Stainless Steel
Tension / Compression
C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
2,000 to 10,000
Accuracy (%FSO)
0.20
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
25,000 to 2,000,000
Accuracy (%FSO)
0.20
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Range (lbf)
2,500 to 120,000
Accuracy (%FSO)
2.00
Construction
Stainless Steel
Tension / Compression
C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Affordable, easy-to-use, single-channel conditioner designed for input of pressure, force and temperature measured by DC-excited strain gauge resistor bridge transducers. Ideal for applications where the sensor is exposed to conditions of high temperature, high humidity and corrosiveness.
General purpose, single-channel conditioner designed to provide variable bridge excitation and signal conditioning our pressure, force and temperature strain gauge, resistor bridge transducers. NEMA 4 enclosure provides easy access to input/output terminations and signal adjustments in an IP65 housing.
Range (psi)
15 to 50,000
Reference
G, A
Accuracy (%FSO)
±0.05
CTR (°F)
-30 to +170
Sealing
Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (±inches)
0.50 to 3.00
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
DC/DC
Output:
DC/DC
±2.2 Vdc
Range (±inches)
0.50 to 8.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.50 to 8.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.50 to 8.00
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.50 to 8.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
±2.2 Vdc
Range (±inches)
0.50 to 3.00
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.50 to 3.00
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.50 to 3.00
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
DC/DC
Output:
DC/DC
±2.2 Vdc
Range (lbf)
25 to 300
Accuracy (%FSO)
0.05
Construction
Aluminum
Tension / Compression
T/C
Sealing
Environmental Ingress
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (lbf)
500 to 5,000
Accuracy (%FSO)
0.10
Construction
Stainless Steel
Tension / Compression
T/C
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
100 to 5,000
Accuracy (%FSO)
0.05
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Stellar Technology’s LVDT mounting blocks offer a means of supporting our linear displacement transducers. We suggest that at least 2 are used per transducer and for longer stroke units 3 or 4 mounting blocks.
Range (psi)
500 to 20,000
Reference
G, A
Accuracy (%FSO)
±0.50
CTR (°F)
-30 to +170
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
100 to 5,000
Reference
G
Accuracy (%FSO)
±0.50
CTR (°F)
+30 to +130
Output:
Low Level
1-2 mV/V
Range (psi)
100 to 5,000
Reference
G
Accuracy (%FSO)
±0.50
CTR (°F)
+30 to +130
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
2,000 to 20,000
Reference
G, A
Accuracy (%FSO)
±0.50
CTR (°F)
-65 to +250
Output:
Low Level
3 mV/V
Range (±inches)
0.03 to 0.50
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
AC/AC
Output:
AC/AC
mV/V
Range (±inches)
0.01 to 0.50
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
AC/AC
Output:
AC/AC
mV/V
Range (lbf)
3,000 to 200,000
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Hermetic
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
30,000 to 50,000
Accuracy (%FSO)
0.25
Construction
Stainless Steel
Tension / Compression
C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (±inches)
0.04 to 0.20
Accuracy (%FSO)
±0.25
Armature Type
Spring Return
Power / Output Type
AC/AC
Output:
AC/AC
mV/V
Range (±inches)
0.04 to 0.20
Accuracy (%FSO)
±0.25
Armature Type
Air Push
Power / Output Type
AC/AC
Output:
AC/AC
mV/V
Range (lbf)
100 to 1,000
Accuracy (%FSO)
0.15
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Range (lbf)
100 to 1,000
Accuracy (%FSO)
0.15
Construction
Stainless Steel
Tension / Compression
C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (In-Line)
Digital
CANbus, RS-232, RS-485 (In-Line)
Provides a 6-digit digital readout for 0-20 mA current and ±10 V inputs in a NEMA 4X enclosure off of 85-265 VAC or 12/24 Vdc power. Four multi-function keys are included to enable output tailoring and display programmability.
A 6-digit digital readout for a single channel, strain gauge bridge input to 300 mV (unipolar) and ±250 mV (bipolar) with up to 10 Vdc excitation. The unit works off of 85-265 VAC or 12/24 Vdc power in a NEMA 4X enclosure. Four multi-function keys are included to enable output tailoring and display programmability.
Range (lbf)
2,000 to 2,000,000
Accuracy (%FSO)
0.25
Construction
Stainless Steel
Tension / Compression
C
Sealing
Hermetic
Output:
Low Level
2 mV/V
Accuracy (%FSO)
L = ±0.01
Construction
Stainless Steel
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Provides a 4-digit digital readout for 0-20 mA current and ±10 V voltage inputs off of 85-265 VAC (12/24 Vdc optional) power in a cost-effective, NEMA 4X sealed enclosure design. Four function keys are included to toggle through output fields and to facilitate display programmability.
Range (lbf)
5,000 to 120,000
Accuracy (%FSO)
0.20
Construction
Stainless Steel
Tension / Compression
T
Sealing
Hermetic
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (±inches)
0.10 to 0.40
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.10 to 0.40
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (psi)
15 to 40,000
Reference
A
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-65 to +250
Sealing
Hermetic
Output:
Low Level
3 mV/V
Range (psi)
15 to 40,000
Reference
A, S
Accuracy (%FSO)
L = ±0.20, H = ±0.20, R = ±0.10
CTR (°F)
-60 to 200
Sealing
Hermetic
Output:
Analog
0-5 Vdc
Range (psi)
15 to 50,000
Reference
G, A
Accuracy (%FSO)
±0.25 (BFSL)
CTR (°F)
+30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
50 to 50,000
Reference
G, A
Accuracy (%FSO)
±0.25
CTR (°F)
+30 to +130
Sealing
Welded
Output:
Low Level
3 mV/V
A completely portable, battery powered, strain gage bridge output indicator, packaged in a small, robust IP65 / NEMA 4 enclosure. Two separate ranges are available, enabling this instrument to read and display two different units of measure.
Range (psi)
15 to 40,000
Reference
G, A, S
Accuracy (%FSO)
±0.25
Sealing
Hermetic
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.50 to 18.50
Accuracy (%FSO)
±0.50
Armature Type
Captive Guide
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.50 to 8.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.50 to 8.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.10 to 8.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.50 to 3.00
Armature Type
Spring Return
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.10 to 3.00
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.10 to 3.00
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Range (±inches)
0.04 to 0.50
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
AC/AC
Output:
AC/AC
mV/V
Range (±inches)
0.04 to 0.50
Accuracy (%FSO)
±0.50
Armature Type
Spring Return
Power / Output Type
AC/AC
Output:
AC/AC
mV/V
Range (±inches)
0.50 to 4.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
4-20 mA
Range (±inches)
0.50 to 4.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
AC/AC
Output:
AC/AC
V/V
Range (±inches)
0.50 to 4.00
Accuracy (%FSO)
±0.50
Armature Type
Free Unguided
Power / Output Type
DC/DC
Output:
DC/DC
±5 Vdc or 0-10 Vdc
Ideal for precise micro-position measurements, our ultra-miniature (LVDTs) provide accurate, repeatable measurement. Inductive contact, non-contact, slide, and spring-actuated sensors are available in various stroke lengths- ideal in spaces where traditional LVDTs are too large.
Range (lbf)
250 to 30,000
Accuracy (%FSO)
0.50
Construction
Stainless Steel
Tension / Compression
T/C
Sealing
Welded
Output:
Low Level
2 mV/V
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc (Integral)
Digital
CANbus, RS-232, RS-485 (Integral)
Range (psi)
5,000 to 20,000
Reference
G
Accuracy (%FSO)
±0.20
Construction
Stainless Steel or Inconel
CTR (°F)
-30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
5,000 to 20,000
Reference
G
Accuracy (%FSO)
±0.20
Construction
Stainless Steel or Inconel
CTR (°F)
+30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
5,000 to 20,000
Reference
G
Accuracy (%FSO)
±0.20
Construction
Stainless Steel or Inconel
CTR (°F)
+30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485
Range (psi)
10,000 to 25,000
Reference
G
Accuracy (%FSO)
±0.20
Construction
Stainless Steel or Inconel
CTR (°F)
-30 to +130
Sealing
Welded
Output:
Analog
4-20 mA, 0-5 Vdc, 0-10 Vdc
Digital
CANbus, RS-232, RS-485