- Models:
- GT2250 - CSA I.S. CLI DIVI
- GT23XX - ATEX Flameproof
- GT2450 - ATEX I.S. CLI DIVI
- GT25XX - CSA Flameproof
Product Hi-Lites:
- Hazardous Certifications
|
|
 |
|
|
|
 |
|
 |
|
|
 |
|
|
 |
|
|
|
Hazardous Location Pressure Transmitters
- Stellar Technology offers a comprehensive line of products for hazardous areas. The models listed in this product offering are either mechanically capable of withstanding flameproof/explosion proof areas or electrically capable of withstanding operation in intrinsically safe areas.
STI can provide either North American approvals or Worldwide approvals. Several of the units have dual approvals for those equipment manufacturers requiring this capability.
Let our expertise assist you in your next "Application-Solution"
- Our GT2250 Upgrade provides- CSA certification: Exia CL I, GROUPS ABCD. T4A (US & Canada)
- Our GT23XX Upgrade provides- Certification: EExd IIC T6
- Our GT2450 Upgrade provides- Certification: EEx ia IIC T4
- Intrinically safe areas require Barriers, which STI is pleased to offer.
|
|
|
 |
ATEX Certified Models: |
|
GT2350 |
Flameproof |
II 1 G EEx d IIC T5 |
|
GT2450 |
Intrinsically Safe |
II 1 G EEx ia IIC T5 |
|
|
|
|
 |
- EMC Directive 89/336/EEC
- European Pressure Equipment Directive 97/23/EC
|
|
|
|
 |
Canadian Standards Association Certified Models: |
|
GT2250 |
Intrinsically Safe |
Class I, Div.1, GROUPS ABCD |
|
|
Non-Incendive |
Class I, Div.2, GROUPS ABCD |
|
|
|
|
|
GT2550 |
Explosion Proof |
Class I, Div.1, GROUPS ABCD |
|
|
Non-Incendive |
Class I, Div.2, GROUPS ABCD |
|
|
|
|
|
|
|
|
|
|
|
|
|